WF-EN-55
Support testing of large displacement engines for drones
measuring thrust, torque, fuel consumption, and cylinder temperature etc.
BASIC PARAMETER
Basic Parameters | Operating Temp | 0 〜 +40 ℃ |
Operating Humidity | ≦80% No condensation | |
Storage Temp | -20 〜 +60 ℃ | |
Storage Humidity | ≦ 90% No condensation | |
Maximum Installed Weight | 35KG | |
Recommended Test Engine | 110~550CC | |
Max Propeller | 65 in | |
Equipment Power Supply UPS system | AC Power Supply | AC100-277V 2.8A |
Equipment Power Consumption | DC 24V 0.5A | |
Battery System | 12V/24V 20/10AH(CCA≧200A) | |
Charging Current | 15.4/7.7A MAX | |
Device Communication | Main Serial Port | RS-422@460800 |
Temperature Acquisition Serial Port | RS-485@115200 | |
Wired Communication | High-speed 422 via USB module + 485 via USB module | |
Wireless Data Transmission | Device Type | Dual-channel 422/485 full-duplex wireless transmission |
Working Frequency Band | 2400 MHz | |
Transmitting Power | 20 dBm | |
Communication Distance | 200 m | |
Engine Control | IO1-ECU Power Supply | 15A Relay (battery powered) |
IO2-Electric Starter | 300A Relay (battery powered) | |
IO3-Ignition 1 | 15A Relay (ground) | |
IO4-Ignition 2 | 15A Relay (ground) | |
IO5-Oil Pump 1 | 15A Relay (battery powered) | |
IO6-Oil Pump 2 | 15A Relay (battery powered) | |
IO7-Servo Power Supply | 15A Relay (battery powered) | |
Throttle servo PWM signal output 1 | 333Hz 800-2200μs | |
Choke servo PWM signal output 2 | 333Hz 800-2200μs | |
Thrust | Range | 150 kg |
Resolution | 0.01 kg | |
Instantaneous Overload | 200%F.S. | |
Destructive Overload | 400%F.S. | |
Accuracy | 0.2%+0.2%FS | |
Torque | Range | 150 N·m |
Resolution | 0.01 N·m | |
Instantaneous Overload | 200%F.S. | |
Destructive Overload | 400%F.S. | |
Sensor Accuracy | 0.2%+0.2%F.S. | |
Optical Speed | Range | 0 〜 15000 RPM |
Resolution | 1 RPM | |
Accuracy | 0.05%+0.05%FS | |
Pulse Speed | Range | 0 〜 60000 RPM |
Resolution | 1 RPM | |
Accuracy | 0.05%+0.05%FS | |
Supported Level | 1-5V | |
Cylinder Head Thermocouple *2 | Type | PT100 |
Range | -20〜250 ℃ | |
Accuracy | ± 0.3 ℃ | |
Exhaust Thermocouple*2 | Type | K Type |
Range | -20〜650 ℃ | |
Accuracy | 0.05%+1℃ | |
Spare Temperature Interface*4 | Type | PT100/K Type |
Range | Same as above | |
Acquisition Accuracy | Same as above | |
Environmental Module | Barometric pressure range | 30 〜 110 kpa |
Barometric pressure resolution | 0.01 kpa | |
Barometric pressure accuracy | ±0.06 kpa | |
Ambient temperature range | -40 〜 85 ℃ | |
Ambient temperature resolution | 0.1 ℃ | |
Ambient temperature accuracy | ±1 ℃ | |
Humidity range | 0 〜 100%RH | |
Humidity resolution | 1 %RH | |
Humidity accuracy | ±3% |
MET-E ENGLISH SOFTWARE
Seven Test Modes
Custom Supported
Long-term Testing Supported
Test Report Output
Standard Version 10Hz
MET-E English Software
The software supports comparison of multiple test reports and customization of constant speed.
INQUIRY NOW
We specialize in collaboratingwith our clients to create a shared vision for powerful stories
Contact Us